Guarded Bin Tipper for 600 Litre Dolaf Bins
BTH/600/1000/B/G
Guarded Bin Tipper Description
This guarded bin tipper is designed to lift and tip a 600 Litre Dolaf bin at a height
of 1000mm. The guarded bin tipper is constructed from Grade 304 stainless steel
and is a fully TIG welded construction throughout. This guarded bin tipper would
be powered via a hydraulic powerpack and would tip the containers by the extension
of a pair of stainless steel hydraulic cylinders. The guarded bin tipper will operate
on a 'dead mans handle' principle and is designed to be bolted to the floor. The
hydraulic cylinders will be fitted with hydraulic fuses to prevent the bin from
falling in the unlikely event of a hose failure.
Safety Guard to PD 5304:2005 Safety of Machinery
The safety guard is constructed from 40 x 40 x 3mm stainless steel box section and
3mm wire, 40mm aperture stainless steel weld mesh to meet the requirements of PD
5304:2005 Safety of Machinery. It would enclose the guarded bin tipper to a height
of 2200mm on two sides, 800mm at the front with a hinged door on the fourth side.
The guard door is electrically and mechanically interlocked preventing the guarded
bin tipper from operating with the door open. In addition, the guard door can only
be opened when the lifting carriage is at the full down position.
Guarded Bin Tipper Specification
|
DESCRIPTION
|
HYDRAULIC GUARDED BIN TIPPER
|
|
MODEL No.
|
BTH/600/1000/B/G
|
|
CAPACITY
|
600Kgs
|
|
TIPPING HEIGHT
|
1000mm
|
|
TIPPING ANGLE
|
120 DEGREES
|
|
MACHINE HANDING
|
LEFT OR RIGHT HAND AVAILABLE
|
|
TIPPING CHUTE
|
OPTIONAL
|
|
CONTAINER DESCRIPTION
|
600 LITRE DOLAF BIN
|
|
BASE ARRANGEMENT
|
BOLTED TO THE FLOOR
|
|
CONTROL CIRCUIT
|
24Vac (STANDARD)
|
|
ELECTRICAL RATING
|
IP65
|
|
POWERPACK
|
415V, 50 Hz, 3 PHASE & NEUTRAL
|
Guarded Bin Tipper Application Story
This fully guarded bin tipper was loaded with a Dolaf bin via a hand pallet truck
and tipped the contents of the bin onto a sorting table. The tipping operation was
fully automated such that a bin could be loaded, the safety gate closed and a cycle
‘Start’ push button pressed. The guarded bin tipper then lifted to full up, paused
to allow the entire product to exit and then returned to the full down position.
|